Controllable, programmable linear DC source » LAB/SL

VOLTAGE: UP TO 120V | CURRENT: UP TO 30A | POWER: UP TO 2400W

LAB/SL

  • Linear laboratory power supply with integrated electronic load
  • No thyristor pre-regulation, very low ripple
  • Various interfaces
  • Protection against short-circuit, overload and overtemperature
  • Constant current and constant voltage
  • Fast control times approx. 250µS
Standard interfaces:Operation via front
Optional interfaces:IEEE 488, RS232, Analog - Interfaces

Do you have any questions about the product?
We are there for you: +49 (0) 6205 - 3948-0 or info@et-system.de

More information about the linear DC source LAB/SL

» Technical information and options-+

» Technical information and options

Mains Connection, Switchable:115/230 VAC ± 10%
Insulation: 3700 VAC; 4250 VDC
Line Regulation (± 10 %) CV: 0.0125 %
Line Regulation (± 10 %) CC: 0.02 %
Load Regulation (10 – 90 %) CV: 0.0125 %
Load Regulation (10 – 90 %) CC: 0.02 %
Programming Accuracy: < ± 0.5 %
Offset: < ± 4.0 mV
Residual Ripple (Vpp) CV: < 4.0 mA (< 8.0 mA LAB/SL 8)
Temperature Coefficient: 25 ppm/°C
Recovery Time: < 100 µs
Settling Time: < 500 µs (typ. < 250 µs)
Sense Line Compensation (V/Line): 1.0 V (2.0 V LAB/SL 8)

Display:3.5 digits for Voltage (U) and Current (C)
Protection: OC/OV/OT/OP
Analog Interface: 0 – 5(10)V see options
Galvanically Isolated Analog Interface: 0 – 5(10)V see options
Interface RS 232:
Interface RS 485:
Interface IEEE 488:

Operating Temperature Range: 0 – 50°C
Operating Humidity: 30 – 90% (non-condensing)
Power Derating 50 – 70°C: -2% per °C
Cooling 120/240 W: Forced air front to back
Storage Temperature Range: -45 to +85°C
Storage Humidity: 10 – 95% (non-condensing)

» Options-+

» Options

/ATE: Without display and controls
/AI5: Analogue interface 0 - 5 VDC
/AI10: Analogue interface 0 - 10 VDC
/ATI5: Analogue interface galvanically isolated 0 - 5 VDC
/ATI10: Analogue interface galvanically isolated 0 - 10 VDC
LT IEEE: 488 interface, listener und talker

LTRS232: RS 232 interface, listener und talker
LTRS485: RS 485 interface, listener und talker
LT+LTRS232: IEEE 488.2 & RS 232, Listener und Talker
LT+LTRS485: IEEE 488.2 & RS 485, Listener und Talker
/10POT:  Potentiometer mit Scala

» Overview of device types-+

» Overview of device types

Description       Power       Source            Load         Current    Dimension
LAB/SL 8          120W        0 – 8V            1 – 8V       0 – 15A   112 x 222 x 360 mm
LAB/SL 15        120W        0 – 15V          1 – 15V     0 – 8A     112 x 222 x 360 mm
LAB/SL 30        120W        0 – 30V          1 – 30V     0 – 4A     112 x 222 x 360 mm
LAB/SL 60        120W        0 – 60V          1 – 60V     0 – 2A     112 x 222 x 360 mm
LAB/SL 120      120W        0 – 120V        1 – 120V   0 – 1A     112 x 222 x 360 mm

 

Back