Diese Website verwendet Cookies. Wenn Sie die Website und ihre Angebote nutzen und weiter navigieren, akzeptieren Sie diese Cookies. Mit Hilfe der Einstellungen Ihres Browsers können Sie dies ändern.
Hier können Sie sich über unsere Datenschutz-Richtlinien informieren
Akzeptieren
Schattenwurf

DC-Sources - Switch mode

Voltage: up to 1500 V, Current: up to 50,000 A, Power: up to 1 MW



  • From 750 W to 1 MW
  • Output voltages up to 1,500 V
  • Output currents up to 50,000 A
  • Quiet operation, ensuring that it is pleasant to work within the vicinity of the unit
  • Very easy to control via front panel
  • Information via graphic display
  • Constant voltage, current, resistance, power operation and simulation of PV arrays
  • Create any type of voltage or current curve via memory card or digital interface (sequential operation)
  • Script operation, in conjunction with the Datalog function, enables an independent stand-alone test field to be set up
  • Standard integrated ATI 5/10 galvanically isolated analogue interface: 0 – 5 V or 0 – 10 V (user selectable) and RS232, master/slave (LAB/HP and LAB/SMS), soft interlock
  • Master/slave interface to parallel and series circuits (LAB/HP and LAB/SMS)
  • Filter functions which can be adjusted for analogue interface
  • Digital interfaces IEEE488, RS485, USB and LAN (optional)
  • SD card slot (optional)
  • Datalog function: Current operating values are saved to the memory card at adjustable time intervals, SD card (optional)
  • Voltage rise time and current rise time (U and I slopes) are adjustable
  • Umax and Imax can be set by the user in order to limit output voltage or output current
  • A switch-off time can be set for the unit once the start button has been pressed
  • Create U/I output characteristics which can be saved (e.g. for PV-Sim, shading)
  • “High speed” optional secondary rise and fall time for the DC output voltage is reduced by a factor of 10 compared to standard times, on average
  • Autorange optional down to 33%
  • OVP, OTP, UVP and OCP protective functions
  • Special versions available on request


Economy Line

750 W to 195 kW


LAB SMP/E 750 - 2.400 W

  • 750 W to 2.4 kW
  • Output voltages up to 1,200 V
  • Output currents up to 160 A
  • Quiet operation, ensuring that it is pleasant to work within the vicinity of the unit
  • Constant current and voltage
  • Standard integrated ATI 5/10 galvanically isolated analogue interface: 0 – 5 V or 0 – 10 V (user selectable) and RS232
  • Digital interfaces IEEE488, RS485, USB and LAN (optional)
  • “High speed” feature (optional)
    The secondary rise and fall time for the DC output voltage is shortened by a factor of 10 in comparison to the standard times, on average.
  • Autorange function optional down to 33%
  • Special versions available on request

LAB SMS/E 3 - 10 kW

  • 3 kW to 10 kW
  • Output voltages up to 1,500 V (2,000 V)
  • Output currents up to 500 A
  • Quiet operation, ensuring that it is pleasant to work within the vicinity of the unit
  • Constant current and voltage
  • Standard integrated ATI 5/10 galvanically isolated analogue interface: 0 – 5 V or 0 – 10 V (user selectable) and RS232
  • Digital interfaces IEEE488, RS485, USB and LAN (optional)
  • “High speed” feature (optional)
    The secondary rise and fall time for the DC output voltage is shortened by a factor of 10 in comparison to the standard times, on average.
  • Autorange function optional down to 33%
  • Special versions available on request

Lab HP/E 5 - 195 kW

  • 5 kW to 195 kW
  • Output voltages up to 1,500 V (2,000 V)
  • Output currents up to 9,750 A
  • Quiet operation, ensuring that it is pleasant to work within the vicinity of the unit
  • Constant current and voltage
  • Standard integrated ATI 5/10 galvanically isolated analogue interface: 0 – 5 V or 0 – 10 V (user selectable) and RS232
  • Digital interfaces IEEE488, RS485, USB and LAN (optional)
  • “High speed” feature (optional)
    The secondary rise and fall time for the DC output voltage is shortened by a factor of 10 in comparison to the standard times, on average.
  • Autorange function optional down to 33%
  • Special versions available on request

Economy Line extended

750 W to 195 kW


Professional Line

750 W to 1 MW


LAB SMP 750 - 2.400 W

  • 750 W to 2.4 kW
  • Output voltages up to 1,200 V
  • Output currents up to 160 A
  • Quiet operation, ensuring that it is pleasant to work within the vicinity of the unit
  • Very easy to control via front panel
  • Information via graphic display
  • Constant voltage, current, resistance, power operation and simulation of PV arrays
  • Create any type of voltage or current curve via memory card or digital interface (sequential operation)
  • Script operation, in conjunction with the Datalog function, enables an independent stand-alone test field to be set up
  • Standard integrated ATI 5/10 galvanically isolated analogue interface: 0 – 5 V or 0 – 10 V (user selectable) and RS232, soft interlock
  • Filter functions which can be adjusted for analogue interface
  • Digital interfaces IEEE488, RS485, USB and LAN (optional)
  • SD card slot (optional)
  • Datalog function: Current operating values are saved to the memory card at adjustable time intervals, SD card (optional)
  • Voltage rise time and current rise time (U and I slopes) are adjustable
  • Umax and Imax can be set by the user in order to limit output voltage or output current
  • A switch-off time can be set for the unit once the start button has been pressed
  • Create U/I output characteristics which can be saved (e.g. for PV-Sim, shading)
  • “High speed” optional
    The secondary rise and fall time for the DC output voltage is reduced by a factor of 10 compared to standard times, on average
  • Autorange optional down to 33%
  • OVP, OTP, UVP and OCP protective functions
  • Special versions available on request

LAB SMS 3 - 80 kW

  • 3 kW to 80 kW
  • Output voltages up to 1,500 V (2,000 V)
  • Output currents up to 4,000 A
  • Quiet operation, ensuring that it is pleasant to work within the vicinity of the unit
  • Very easy to control via front panel
  • Information via graphic display
  • Constant voltage, current, resistance, power operation and simulation of PV arrays
  • Create any type of voltage or current curve via memory card or digital interface (sequential operation)
  • Script operation, in conjunction with the Datalog function, enables an independent stand-alone test field to be set up
  • Standard integrated ATI 5/10 galvanically isolated analogue interface: 0 – 5 V or 0 – 10 V (user selectable) and RS232, master/slave (LAB/HP and LAB/SMS), soft interlock
  • Master/slave interface to parallel and series circuits (LAB/HP and LAB/SMS)
  • Filter functions which can be adjusted for analogue interface
  • Digital interfaces IEEE488, RS485, USB and LAN (optional)
  • SD card slot (optional)
  • Datalog function: Current operating values are saved to the memory card at adjustable time intervals, SD card (optional)
  • Voltage rise time and current rise time (U and I slopes) are adjustable
  • Umax and Imax can be set by the user in order to limit output voltage or output current
  • A switch-off time can be set for the unit once the start button has been pressed
  • Create U/I output characteristics which can be saved (e.g. for PV-Sim, shading)
  • “High speed” optional
    The secondary rise and fall time for the DC output voltage is reduced by a factor of 10 compared to standard times, on average
  • Autorange optional down to 33%
  • OVP, OTP, UVP and OCP protective functions
  • Special versions available on request

LAB HP 5 kW - 1 MW

  • 5 kW to 1 MW
  • Output voltages up to 1,500 V (2,000 V)
  • Output currents up to 50,000 A
  • Quiet operation, ensuring that it is pleasant to work within the vicinity of the unit
  • Very easy to control via front panel
  • Information via graphic display
  • Constant voltage, current, resistance, power operation and simulation of PV arrays
  • Create any type of voltage or current curve via memory card or digital interface (sequential operation)
  • Script operation, in conjunction with the Datalog function, enables an independent stand-alone test field to be set up
  • Standard integrated ATI 5/10 galvanically isolated analogue interface: 0 – 5 V or 0 – 10 V (user selectable) and RS232, master/slave (LAB/HP and LAB/SMS), soft interlock
  • Master/slave interface to parallel and series circuits (LAB/HP and LAB/SMS)
  • Filter functions which can be adjusted for analogue interface
  • Digital interfaces IEEE488, RS485, USB and LAN (optional)
  • SD card slot (optional)
  • Datalog function: Current operating values are saved to the memory card at adjustable time intervals, SD card (optional)
  • Voltage rise time and current rise time (U and I slopes) are adjustable
  • Umax and Imax can be set by the user in order to limit output voltage or output current
  • A switch-off time can be set for the unit once the start button has been pressed
  • Create U/I output characteristics which can be saved (e.g. for PV-Sim, shading)
  • “High speed” optional
    The secondary rise and fall time for the DC output voltage is reduced by a factor of 10 compared to standard times, on average
  • Autorange optional down to 33%
  • OVP, OTP, UVP and OCP protective functions
  • Special versions available on request

Professional Line with Touch-Display

750 W bis 1 MW


Rückruf
anfordern
Produktkonfigurator
aufrufen
Produktvorführung
anfordern
Kundenbesuch
anfordern