AC/DC

Power up to 1 MW and 1.500 VDC



  • Efficiency up to 94 %
  • Compact design
  • Active parallel mode
  • Simple front panel operation
  • Constant current, voltage, resistance and power operation
  • VI, VIP, VIR Modes & Simulation of PV-Arrays
  • Script Control: process programming of sequences and characteristics
  • User defined output characteristics created via memory card or digital interface
  • Digital interfaces IEEE 488.2 (GPIB), RS-232/485, USB and LAN
  • Special versions available on request
  • Galvanically isolated analogue Interface 0 – 5 V or 0 – 10 V (user selectable)
  • Storable V/I wave forms (e.g. for PV simulation and sequential control)
  • Large graphical display with clear indication of actual output values
  • Data logging function: Output values can be saved at adjustable intervals to a memory card
  • Stand-alone test rig possibility with script operation in combination with data logging function
  • Adjustable OVP, Vmax and Imax in addition to normal output voltage and current limit settings
  • MPP-Tracking


LAB HP/E 5 - 250 kW

ECONOMY LINE
• Laboratory switch mode Power Supply
• from 3 U

  • Efficiency up to 94 %
  • Compact design
  • Active parallel connectable
  • Easiest operation via front panel
  • Constant current, voltage
  • Digital interfaces IEEE 488, RS 485, USB and LAN (optional)
  • Standard integrated ATI 5/10 galvanically isolated analogue interface: 0 – 5 V or 0 – 10 V (user selectable) and RS 232
  • 7-segment display
  • Special version on request
  • Umax and Imax randomly selectable to limit maximum output voltage and current

LAB/HP 5 - 250 kW

PROFESSIONAL LINE
• Laboratory switch mode Power Supply
• from 3 U

  • Efficiency up to 94 %
  • Compact Design
  • Active parallel and serial connectable
  • Easiest operation via front panel
  • Constant Current, Voltage, Resistance and Power Operation
  • Randomly programmable Memory Locationsfor U/I waves
  • UI, UIP, UIR Mode, Simulation of PV-Arrays
  • Script Control: process programming of sequences and characteristics
  • Creating user defined output characteristicsvia memory card or digital interface
  • Digital Interfaces IEEE 488, RS232/485, USB and LAN (optional)
  • Galvanically isolated Analogue Interface 0 - 5 V or0 - 10 V (user selectable; optional)
  • Storable U/I wave forms (e.g. for PV simulation and sequential control)
  • Graphical Display
  • Special version on request
  • Datalog function: operation values can be savedin an adjustable interval to a memory card
  • Script operation in combination with Datalogfunction allows an independent stand-alone test field setup
  • Umax and Imax randomly selectable to limit maximum output voltage and current

LAB/SMS/E 3 - 10 kW

ECONOMY LINE
• Laboratory switch mode Power Supply
• 2 U

  • Efficiency up to 94 %
  • Compact design
  • Active parallel connectable
  • Easiest operation via front panel
  • Constant current, voltage
  • Digital interfaces IEEE 488, RS 485, USB and LAN (optional)
  • Standard integrated ATI 5/10 galvanically isolated analogue interface: 0 – 5 V or 0 – 10 V (user selectable) and RS 232
  • 7-segment display
  • Special version on request
  • Umax and Imax randomly selectable to limit maximum output voltage and current

LAB/SMS 3 - 10 kW

PROFESSIONAL LINE
• Laboratory switch mode Power Supply
• 2 U

  • Efficiency up to 94 %
  • Compact Design
  • Active parallel and serial connectable
  • Easiest operation via front panel
  • Constant Current, Voltage, Resistance and Power Operation
  • Randomly programmable Memory Locationsfor U/I waves
  • UI, UIP, UIR Mode, Simulation of PV-Arrays
  • Script Control: process programming of sequences and characteristics
  • Creating user defined output characteristicsvia memory card or digital interface
  • Digital Interfaces IEEE 488, RS232/485, USB and LAN (optional)
  • Galvanically isolated Analogue Interface 0 - 5 V or0 - 10 V (user selectable; optional)
  • Storable U/I wave forms (e.g. for PV simulation and sequential control)
  • Graphical Display
  • Special version on request
  • Datalog function: operation values can be savedin an adjustable interval to a memory card
  • Script operation in combination with Datalogfunction allows an independent stand-alone test field setup
  • Umax and Imax randomly selectable to limit maximum output voltage and current

LAB/SMP/E 750 - 2.400 W

ECONOMY LINE
• Laboratory switch mode Power Supply
• from 1 U

  • Efficiency up to 94 %
  • Compact design
  • Active parallel connectable
  • Easiest operation via front panel
  • Constant current, voltage
  • Digital interfaces IEEE 488, RS 485, USB and LAN (optional)
  • Standard integrated ATI 5/10 galvanically isolated analogue interface: 0 – 5 V or 0 – 10 V (user selectable) and RS 232
  • 7-segment display
  • Special version on request
  • Umax and Imax randomly selectable to limit maximum output voltage and current

LAB/SMP 750 - 2.400 W

PROFESSIONAL LINE
• Laboratory switch mode Power Supply
• from 1 U

  • Max. Voltage 1200 VDC and max. current 160 A
  • Compact design 2,4kW in 1 U
  • Active parallel mode Master - Slave
  • User comfort via front panel operation
  • CC ,CV, CR and CP mode standard
  • Storable space for freely programmable U/I Curves, playable over an external SD card
  • Storable U/I curves (e.g. for PV-Simulation and sequential control)
  • UI, UIP, UIR mode, simulation of PV graphs
  • Script Control: process programming of sequences and characteristics
  • Creation of user-defined output graphs via memory card or digital interface
  • Data log function: current operating values are saved to the memory card within an adjustable interval
  • Graphic Display
  • Analogue Interface 5/10 VDC to set and read out, (option)
  • Digital interfaces IEEE 488, RS232/485, USB and LAN (option)
  • Galvanic isolated analog interface: 0..5 V or 0..10 V (user selectable, option)
  • Line i/p available for worldwide using
  • Script control combined with the data log function enables the build-up of an independent „stand alone“ testing position
  • User adjustable values for Umax and Imax enables limitation of output voltage/output current
  • Special versions on request

LAB/S 500 - 4500 W

• Laboratory linear Power Supply

  • Precision linear DC Sources
  • Low ripple
  • Thyristor pre-regulated
  • CV/CC modes with LED indication
  • Short circuit-, overload and over temperature protected
  • Optional IEEE 488, RS232, Analogue interfaces
  • 3 phase input option

LAB/SL 120 - 240 W

• Laboratory linear DC-Sources
• integrated Electronic Load

  • Linear controlled DC laboratory power supply
  • Very low ripple
  • Optional range of interfaces
  • Electronic Load mode build in
  • Constant voltage & constant current modes
  • Short circuit-, overload and over temperature protected
  • Fast response time of typically <250µS

LAB/SLR 120 - 240 W

• Laboratory linear DC-Sources
• integrated Electronic Load
• automatic ranging

  • Linear DC Source with automatic ranging
  • Built in Electronic Load free of cost
  • Peak loading (240W & 480W) available for 5mins
  • Low voltage/high current ranges available
  • Short circuit-, overload and over temperature protected
  • Fast response time of typically <250µS

LAB/ACO/IGBT 60.000 W

• High-performance DC-Sources
• IGBT Technology

  • IGBT controlled power unit
  • Voltage up to 400 VDC
  • Current up to 5.000 A
  • Analogue and digital iterfaces (option)
  • Ripple < 1 %
  • Short circuit-, overload and over temperature protected
  • Parallel and Series-Selectable
  • Constant current and constant voltage operation

AB/ACO 1.000.000 W

• High-performance DC-Sources
• Thyristor Technology

  • Thyristor controlled power unit
  • Voltage up to 600 VDC
  • Current up to 50.000 A
  • Short circuit-, overload and over temperature protected
  • Analogue and digital iterfaces (option)
  • Residual ripple < 2 %
  • Constant voltage and constant current operation